電力系統における最近接限界潮流点のモンテカルロ・シュミレーション
スポンサーリンク
概要
- 論文の詳細を見る
This paper describes a method to obtain a point for the shortest distance between a normal operation and a critical point of load flow in electrical power systems by means of Monte Carlo simulation. It also presents characteristics of power distance, voltage distance, and inner products of eigenvectors and voltage difference with respect to the point on the trajectory of minimum search. The critical point is characterized by the zero determinant of Jacobian matrix. The point is known as saddle node bifurcation. We propose a method to calculate the critical point under bus constraints of the load flow equation. A new set of voltages is give by random generator for a step of Monte Carlo simulation. We calculate the power distances and draw a trajectory for the closest bifurcation by the random process. The result shows that the right eigenvector is parallel to the normal line of tangential planes at the closest bifurcation.
- 社団法人 電気学会の論文
- 2003-01-01
著者
関連論文
- 限界潮流計算プログラムについて
- 限界負荷潮流と疎行列処理プログラム
- 電気・電子回路網の混合解析による定式化と過渡現象解析の計算機プログラムについて
- 大域的限界負荷電力潮流計算法
- 電力系統における限界負荷特性について
- 電力系統における電力潮流解の存在領域について
- 電力潮流計算における最近接分岐点の理論的接近法について
- 電力系統における最近接限界潮流点とモンテカルロ・シミュレーション
- 限界電力潮流曲面の探索について
- 伝達関数行列の誘導プログラム
- 動態安定度判定の一計算手法
- 空間曲線追跡による潮流多根