Bubble Size Measurement in a Gas-Liquid Ejector for a Sodium Chloride-Air System
スポンサーリンク
概要
- 論文の詳細を見る
A high speed photographic technique has been employed to measure the Sauter mean diameter of bubbles experimentally in a gas liquid ejector using a sodium chloride-air system. The measured values are compared with the theoretically predicted maximum bubble size diameter using Sprow’s correlation. Bubble size as a function of the liquid flow rate and also of its distance from the throat of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those obtained earlier for the air-water system.
- 2002-04-01
著者
-
Das T.
Department Of Chemical Engineering Indian Institute Of Science
-
RAGHURAM P.
Department of Chemical Engineering, Indian Institute of Science
-
Raghuram P.
Department Of Chemical Engineering Indian Institute Of Science