Description of Multilayered Gamma-Ray Exposure Buildup Factors up to 40 mfp by the Approximating Model
スポンサーリンク
概要
- 論文の詳細を見る
An approximating formula recently proposed by the authors for γ-ray buildup factors of multilayered shields was applied for very thick shields up to 40mfp. For this purpose, modifications were made to the model and the fitting method to improve the data reproducibility. The previous model was expanded so that it included both the plane-normal and point isotropic geometries.<BR>The verification test of the modified model was made for three materials; water, iron and lead. The separately published data of double-layered shields for point isotropic buildup factors calculated by EGS4 from 0.1MeV to 10MeV were used as well as newly calculated data at 1MeV for the plane-normal geometry, and data for the point isotropic geometry of triple-layered shields at 1 and 10MeV.<BR>The present formula generally shows a very good reproducibility of the multilayer buildup factors, even in case of very thick shielding problems. The observed error between the approximating description and the EGS4 data is 15% in the intermediate energy range, about 30% in the higher energy range, and 35% at 0.3MeV. However, the error in the approximation reaches a factor of 4 in the worst case at 0.1MeV.
- 社団法人 日本原子力学会の論文
- 1998-12-25
著者
-
SHIN Kazuo
Department of Nuclear Engineering, Kyoto University
-
Shin Kazuo
Department Of Applied Chemistry Osaka Prefecture University
-
Shin Kazuo
Department Of Nuclear Engineering Kyoto University
-
Hirayama Hideo
High Energy Accelerator Research Organization
関連論文
- Simultaneous Measurement of Prompt Neutrons and Fission Fragments for ^Pu(n_, f)
- Analysis of Neutron Spectra from Thick Targets Bombarded with 710-MeV Alpha Particles by Quantum Molecular Dynamics plus Statistical Decay Model
- Application of the EGS4 Monte Carlo Code to a Study of Multilayer Gamma-Ray Exposure Buildup Factors of up to 40 mfp
- Photocrosslinking System Using Highly-Functionalized Epoxy Crosslinkers Having Degradable Property
- Description of Multilayered Gamma-Ray Exposure Buildup Factors up to 40 mfp by the Approximating Model
- Simulation of the Carrier Trapping Effect in a Schottky CdTe Detector by Considering a Nonuniform Electric Field
- Validity of the Four-Parameter Empirical Formula in Approximating the Response Functions for Gamma-ray, Neutron, and Secondary Gamma-ray Skyshine Analyses
- Calculation of Gamma-Ray Buildup Factors up to Depths of 100 mfp by the Method of Invariant Embedding, (II) : Improved Treatment of Bremsstrahlung
- Comparison of Line Beam Response Function for Gamma-ray Skyshine Analysis Based on Single Scattering Method with the Monte Carlo Calculations
- Validity of the Four-Parameter Empirical Formula in Approximating the Response Functions for Gamma-ray, Neutron, and Secondary Gamma-ray Skyshine Analyses
- Calculation of Gamma-Ray Buildup Factors up to Depths of 100 mfp by the Method of Invariant Embedding, (II) : Improved Treatment of Bremsstrahlung
- Calculation of response function of NE-213 organic liquid scintillator for gamma-rays.
- Fast neutron spectra transmitted through iron and sodium slabs.
- Backscattering of neutrons and secondary gamma-rays from aluminum and lead slabs for 15-MeV neutrons.
- Albedo analytical method for multi-scattered neutron flux calculation in cavity.